Clik here to view.

SQL data base

   Hello All, I am new to the SQL , I configured teststand to MySQL connector version 3.5x as the instrunction I updated in configuration settings.and set the My sql results data base .I am getting the...

View Article


Is there a way to get the name of the Main Sequence test running to send back...

Hi,I am currently trying to get the name of my Main Sequence tests being run and send the name over to my LabVIEW GUI interface for a custom progress bar. However, I am relatively new to TestStand and...

View Article


Running sequence programatically

Hello, I am finding a problem in running sequence file programatically. I referred the example VI (C:\Users\Public\Documents\National Instruments\TestStand 2014 (32-bit)\Examples\TestStand...

View Article

Check for Sequence Running via Model

Hi,Is there a method for checking which sequence has run if I am editing a Model? I am attempting to use a Model to check for when a Main Sequence test is running based on an expression. It would check...

View Article

Returning Step Names

Hi,I am attempting to return Main Sequence Test names in the Main section of the code and ignore any labels, steup and cleanup routine steps in my log. Is there a way to use an expression to do this? I...

View Article


TestStand 2012 csv result processing

The TestStand 2012 results processing has a ascii text file but no .csv file format. I want to have a simple one line per result in csv format; what is the easiest method of achiving this? Not sure how...

View Article

string value test results in default database

Using the default TestStand database, numerical results get stored in the PROP_RESULT.DATA column. Where do results of string value tests get stored?

View Article

the attribute of property

Hi,all:      I am a new learner of teststand, and i have some questions confused! There are two ones: 1: the property attributes     The help file of TS tells we can creat a attribute of property,such...

View Article


can I use Rendezvous only in sigle pass test mode?

Hello, can I use Rendezvous only in sigle pass test mode? see my example attached, I created a new thread and wait them end use Rendezvous,but not success,pls help check,thanks. 

View Article


How can I execute specific Sequences chained with TestStand API

Hi, I have a sequence file with several subsequences. Is there any way to run a bunch of sub sequences with the TestStand API?I am building a TestStand User Interface in LabVIEW and this feature would...

View Article

VI not loadable when inserting GetPropertyValue

Hello,i created a simple dialog in Labview that pops up a window to insert a number that is returned as output and in TestStand set to a StationGlobal.Now the idea was to readout the current value of...

View Article

Custom Menu item in Tools menu - Enable Expression

Hi All, I am trying to add a custom menu item into the TestStand >> Tools menu. This menu item should be accessible only during edit-time and not while any executions are running. I want the menu...

View Article

Can I use active directory to validate users?

Hi Is it possible to link Active Directory to Teststand users ?I would like to do this as it  will allow the user to use their same log in password for the PC. Kind RegardsShakeel

View Article


Image may be NSFW.
Clik here to view.

Error on changing the teststand version from 2014 to 2010 using version selector

Hi All, I am obtaining the following error when I try to change the active version of teststand.   Also I get the same error whenever I launch Teststand 2014. Any inputs in resolving it are welcome....

View Article

TestStand menu, how to show & hide

I have a copy of TestStand where the menu (File, Edit, view, Execut, etc.) is not visible.  How can I make it visible?

View Article


testbench@Bob_schor

Please look through this VI if it needs any improvements or changes specifically in report section @Bob_schor@crossrulz.

View Article

Image may be NSFW.
Clik here to view.

How to get Socket Time shown in OI in Sequence Editor?

Hello Everyone, Is it possible to get the socket time shown in the default NI Semiconductor Test Operator Interface of NI in Sequence Editor?Is there any expression in Sequence Editor that can get this...

View Article


How to correctly start / shutdown TestStand engine using API?

I try to restart TestStand engine between 2 sequence file executions. Using the TS API from VB .Net. Steps: Start the TestStand engine -> execute a sequence -> close the engine -> start the...

View Article

Batch model resource management with step order flexibility

Hey, Teststand folks.  What's the best way in Teststand 2014 to do this?  I'm setting up testing 4 UUTs in parallel using the Batch model.  The test sequence has two parts.  2 UUTs at a time can run...

View Article

Teststand has Detected a Fetal Error !!

an error box called "Teststand has Detected a Fetal Error" accures while the teststand works. And it show up randomly. if we click OK it close the Teststand. Anyone saw thiss ?? and How can I solve it?