Quantcast
Channel: NI TestStand topics
Viewing all 6530 articles
Browse latest View live

Tarjeta NI

$
0
0

Buenos Dias!

 

Agradezco su colaboración, con información de costo y tiempo de entrega de la tarjeta NI según ficha técnica anexa,

 

Gracias,


SMH Flashrunner V19 to V17

$
0
0

Hello. I would like to have this sequence converted from TestStand 19.0.0.170 to TestStand 17.0.0.184.

Thanks

 

Additional Results Step: Log Number As Hex In Report

$
0
0

I am trying to use the Additional Results teststand step to log an Array element (which is a cluster of numeric values) after it is iterated through a for loop. The problem is that I want the value to be displayed as in HEX format not decimal. So instead of logging "2015" in the report I want it to log "0x7DF" Instead. See my current step settings below:

 

Step Settings.png

 

Any idea how to force the step to log these numeric values in hex format?

 

Thanks

Calling a sequence dynamically

$
0
0

Hello, I am new with TestStand(TestStand 2019 32 bit). I just want to ask on how to implement calling of sequence dynamically?

In my case, I have my test Order( Test id's from 1,2,3....). It is predefined already before start of test, what I want to know is how to call a specific sequence/actions in reference to my Test Order.

For ex:

 Pre defined Test Order

Test 1-- Call sequence #1

Test 2--Call sequence #2

Test 3--Call sequence #3

Test 5--Call sequence #5

 

Appreciate your feedback

Datation en microsecond des differents steps de teststand

$
0
0

Bonjour,

 

J'ai actuellement des test Teststand qui font appel a des fonctions d'une Dll CVI Labwindows.

J'aimerai pouvoir scruter tout le fonctionnement de Teststand, avoir la datation de tout les steps de Teststand en envoie et/ou en réception, tracer chaque événement de Teststand temporellement a la micro seconds près.

J'en ai besoin pour une comparaison de timing précis entre des tests sous Teststand 2.0 et Teststand 2010.

 

Merci par avance pour vos réponses 🙂

 

Bonne Journée

Dating of steps in Teststand in microseconds

$
0
0

Hello,


I currently have Teststand tests that use functions from a Dll CVI Labwindows.

I would like to be able to scrutinize all the functioning of Teststand, to have the dating of all the steps of Teststand in sending and / or in reception, to trace each event of Teststand temporally to the nearest microseconds.

I need it for a precise timing comparison between tests under Teststand 2.0 and Teststand 2010.


Thank you in advance for your answers 🙂


Have a good day

Automating Sequence Analyzer with a relative path to sequence file

$
0
0

 

Hi, cross-posting this from Continuous Integration Group as I am not sure where it fits better.

 

I am trying to run a Sequence Analyzer from command line and it does work, but I can't find a way to point it to a sequence file folder nor workspace using parameter or a relative path or anything really. The only way I see is to hard-code paths in to the project. Am I missing something?

 

I'm using this command:

 

 

start /wait "" "%teststand%\Bin\AnalyzerApp.exe" MyAnalyzerProject.tsaproj /analyze /report /save /clearMessagesOnSave /quit

 

 

 

How can I get store procedure output

$
0
0

I have a store procedure that update values into an sql server database. The store procedure return a table with the values that have been updated. In a TestStand's sequence, how can I get  the output values of a store procedure ?

 

Thanks !

 

 


Save OutputMessages at the end of a sequence

$
0
0

I have a TestStand system which generates debug messages as OutputMessages from compiled code modules (LabVIEW PPLs / dll's etc). I need to save the OutputMessages to a file at the end of execution.

I am unable to find a reference to OutputMessages, I am aware of the CopyMessagesToCollection method once I have the aforementioned reference. I cannot do this is in a user interface as that is locked down too and I only have control over the top level sequence.

Thanks in advance.

Publish string to TestStand

$
0
0

Hi,

 

I am wondering if there is a way to publish string result into semiconductor multi test step?

or, do i need to create a dedicated step to publish a string result?

 

by the way, it's multi-site test configuration using Batch model.

The existing Numeric multi test step that i have publishes multiple parameters within it and it publishes a current time to date and time.

what i want to do is publishing date into string format. appreciated any advice.

jonghkim_0-1578878344721.png

jonghkim_1-1578878367236.png

Using ASAM XIL steps to call RT sequences on different targets

$
0
0

I am trying to use these ASAM XIL steps to call RT sequences,  my veristand simulation has multiple targets. How do I specify to which target the RT sequence will get deployed?

Skip final TS status popup since using C#.NET

$
0
0

Hi there,

 

I'm using TS2019 but wrapped in the Simple C#.Net example wrapper. I want the final pass/fail result to be embedded in the C# form and do not want the standard TS pass/fail popup to occur.

 

I've got PostUIMessageEx working so can pass parameters from TS to C# which can then indicate in my GUI the final result, however I cannot find any method of disabling the final TS status popup. Is it possible to disable or bypass in some way?

 

Thanks,

Job Opening

$
0
0

Hello, I am in need of a test engineer for a long term contract job near Binghamton NY.

If this is not appropriate to put on this board, please forgive me and remove the post.

The company is a manufacturer of Fork lifts and similar OEM equipment and a good company to work at.
The location is fairly rural.

 

We have several software test engineers on site but need some help with someone that has Teststand or Veristand background.  Testand is our first choice but either could work.

Please reach out to me at 563-690-4014 if you are interested and send your resume to brian.massman@goe91.com

 

Thank you!

How to use teststand API to set the property of file folder?

$
0
0

Hi All,

    I am a new user on teststand and learning dynamic seq creation function now, I want to store the build seq file to specific folder in the PC with teststand API, But the property of folder is always kept on "Read only" even I changed the property manually. There is run-time error "Access Denied". So I want to know if it is possible to change the property of folder with teststand API? And how to fix it?

   Thanks a lot.

JohnQian_0-1579075360054.png

BR

John

SequenceFilePostStepFailure

$
0
0

Hello 

 

I am using Teststand 2014 and i want to send a message to the UI if a step fails. So, i use the SequenceFilepoststepFailure callback. But the problem is that this callback not only fires when the step fails but also when the sequence fails where the failed step is in. So, it fires twice. Is there a way to let the callback fire only on the step and not on the sequence the step is in ?

 

Thanks in advance


NI Max - automatically switch Driver Session

$
0
0

Hello,

i am using the IVI drivers for my USB instruments and added them to NI MAX

Means i have a logical name and a driver session.

In the testplan i am using the logical name for the init function.

This is working fine.

 

Now the problem:

The USB instrument is changing every day and i have to change always the "Hardware Asset" in the DriverSession.

For USB the resource descriptor is always different and cannot be set to the same value as for LAN instruments.

 

So my question is: How can i automate this? Is there a way to enable more than one HardwareAsset for the DriverSession and the one that is avalable is taken?

 

Thanks

 

.NET DLL documentation from within TestStand

$
0
0

I am creating a .NET DLL for use within TestStand and I have added inline documentation (output as an XML file by VisualStudio)

Is there a way for TestStand to load the documentation and show it as the user selects the .NET methods, a bit like IntelliSense in VisualStudio?

Using Offline Results processing only when the server is unavalible

$
0
0

I'm hoping to make an update to my companies process model to use the Offline Results Processing Utility but only when the network is down or the database is otherwise unavailable.The problem is the Offline Results Processing Utility seems to run every time causing two data-sets to be pushed if the database is up. Is there a way I can use the process model to control rather or not the Offline Results Processing Utility is used?

call Excutable setting

$
0
0

Hi, I have a prblem about how to use the call excutable to call a system command.

I have a  command "cmd /c cd C:\Dxxxx && xxxxx.bat", but i don`t know where i can write the command in teststand. In labview,  I just need to write to the system ec.vi.

Thank you in advance !

Error closing references after creating sequence file in LabView

$
0
0

Hi all,

 

I'm getting an error message about not closed references after creating a sequence file in LabView:

 

References to PropertyObjects were not released properly.
Total number of objects: 49
Number of top-level objects: 5

Note: Some top-level objects may be included if they are referenced by
an incorrectly released top-level object. For example, an unreleased
SequenceContext object references a SequenceFile object.

The following top-level objects were not released:

Files [1 object(s) not released]
SequenceFile #1:
Path: D:\Project1.seq


Type Definitions [1 object(s) not released]
Type Definition #1:
Name: Path


PropertyObjects [2 object(s) not released]
PropertyObject #1:
Type: Number
Value: 0

PropertyObject #2:
Type: Number
Value: 0


And the following uncategorized objects:
TypeUsageList

 

Can you please help me finding out what goes wrong here?

Viewing all 6530 articles