excel database

Hello, I was trying to use an excel database instead access and i´m having problems. First in the ODBC, in DNS-user, I create a new source using "Microsoft Excel Driver (*xls)".Then, in TestStand, in...

View Article


Write to TestStand DataBase

Hi guys! I'm using test stand and saving all data into the standar Database (access), but I have others testers than I'm using just LabView (no TestStand Installed) and I would like save all test data...

View Article


Can't load VI into TestStand

In a new action step, I can't load a call to an Agilent 34970 VI.When I select the VI Path, the UI shows a RED "!" with the  message "LabVIEW: File not found. The file may be in a different location or...

View Article

LabVIEW version '15.0' is not installed

Hi All, When I load an Action step and set it Agilent 34970.lvproj for LabVIEW 2015, the round RED 'I' (exclamation point) says "LabVIEW version '15.0' is not installed."Of course I beg to differ but...

View Article

Tracking down source of Termination

I have a test sequence that is terminating itself once out of every 20 to 30 runs during the middle of execution (not always in the same location) and there's no indication on the report of what is...

View Article


Set Test Socket during Interactive Mode

I'd like to execute a single step using Interactive Mode on a particular Test Socket that I specifiy. In order to do this I suspect that I would set RunState.TestSockets.MyIndex prior to step execution...

View Article

Full OI execution window -does not show running sequence steps

Hi Everyone, We have been using a deployed TestStand application (with full OI) that was working fine for a couple of years and suddenly the execution window does not show any of the running sequence...

View Article

Front Panel working as "UUT information" for Parallel mode

Hey guys,  I'm trying to develop a test software that will use a user interface made in LabVIEW. The idea of the project is to test 32 equipments in parallel. The serial numbers will be acquired with a...

View Article


Display a UserControl from code module in Operator UI with .NET

I am developing a new Operator UI for my test system, but have have a problem.I would like my code modules to have an area in my Operator UI, this area should drawn by the code module while it is...

View Article


NI 600x USB logger

I have a test PC previously installed NI USB 6008 driver with a 6008 logger (lets say its logger A), my question is , can I use another NI usb 6008 logger (logger B) on this same PC? does the PC or...

View Article

Image may be NSFW.
Clik here to view.

error handling with .NET adapter

Is there a way to handle excepetions or errors when using .NET assemblies in TestStand?  For example, I use .NET Serial Port Class to Open a Com port such as pictured below.  If there is an exception,...

View Article

Getting the step's sequence name from a pre-step callback

I was using ResultList[ ].TS.StartTime to get each step's start time. I converted it to seconds for LabVIEW by adding 2082844800 + Engine.SecondsAtStartIn1970UniversalCoordinatedTime to it. In that...

View Article

Sequence using .NET serial port class works only once after TestStand starts

I am using .NET serial port class in a sequence to write and read over the COM port.  Once I start Teststand 2012 and execute the sequence, it works perfect, and I can read back data successully from...

View Article


Sequence End group executes slowly

Hello, I'm facing a problem with TestStand 4.0. At first the execution of the sequences was pretty fast, now it's slow, but the interesting part is that the program halts for a short period at the End...

View Article

How to modify DBLog.dll

Hello, How do we proceed to modify DBLog.dll  to release the connection between TestStand 4.2.1 and MS Access (our database)? Do we have all the needed files in...

View Article


Assignment in conditional expression

Shouldn't this work? I get a status error:unexpected token at the 2nd =: True ? Locals.x = 1 : Locals.x = 2 Stephen

View Article

Break during Shutdown

I've developed a custom UI based on the TestStand 2012 API and have found a strange behavior. I noticed that occasionally my application would not shutdown properly when an execution is running. I find...

View Article


How to setup MySQL server

 Hi every Body,I been trying to setup MySQL into my TestStand Station but I have no luck. I use the NI help http://www.ni.com/tutorial/3604/en/but that document is too old, all software changed. in any...

View Article

Simple sequence editor OI example

I'm looking for a simple LabVIEW OI example that is just a sequence editor.  Does anyone know of any?  All of the examples I have found are either extremely complex (full featured OI example) or are...

View Article

Error - 214682728​4 Controls UTM

I am not sure if this is the right area to put up this issue. I am getting this error 214682728​4  in a CONTROLS UTM while exporting the data to excel. The RTM software (which runs on Labview I think)...

View Article