Quantcast
Channel: NI TestStand topics
Browsing all 6587 articles
Browse latest View live

Documentation generation for sequence file in command line interface [docgen]

Dear TestSand Users,I would like to generate documentation (.txt) for a lot of .SEQ.I identify the use of docgen.seq (sequence provided by NI [see ..\national...

View Article


TestStand DataBase Query

 https://forums.ni.com/t5/NI-TestStand/database-query/m-p/2753326 I make this query for TestStand DataBase query, works fine, but you can modify as wish.

View Article


Locals.UUT customizations deleted upon install of 2014 diskset

Hi,We have customized the UUT data type used in our customized process model to include details such as Manufacturer, hardware rev etc.  We also have the process model seqeuence source controlled under...

View Article

Graph of Multiple Numeric Result displaying measurements and upper and lower...

Is there a way with your graph control to show all the measured values against upper and lower limits in the same graph?. I can display individual lines, but would like to show all the data on the one...

View Article

Couldn't stop the CANalyzer application but 'start' method is running

I am using ActiveX/COM from test stand to start and stop the CANalyzer application. The canalyzer version is 7.6. The Start method works but NOT the stop method.  I am also attaching the simple step I...

View Article


FPGA Board

Hi my freinds,So i have windows 2008 R2, the FPGA Board connected with NI ELVIS II+ but my hardward not detected (FPGA). What the solution? 

View Article

How do I automate the analysis and generation of ethernet packets in TestStand?

I am working with a team interested in using TestStand to automate testing of ethernet hardware. I'm looking for COTS hardware and included software APIs that can be called by TestStand. Specifically,...

View Article

Password Property

Is there a way to get the password "unscrambled" from TestStand?Password PropertySyntaxUser.PasswordData TypeStringPurposeSpecifies the password for the user.RemarksWhen you set this property,...

View Article


Managing shared hardware along multiple executions

Hi, I would like to know if there is a clean and efficient way to manage executions so they can access some shared test hardware in a FIFO method.  The test setup includes four units connected to an RF...

View Article


DAQMx task does not cleanup properly after execution

I have two VIs which are designed to write to various digital output lines (NI PCI digital output card and NI PCIe DAQ) which will control the DUT/s.The channels are hard coded and I have one VI to...

View Article

Test reporting after 8 hours of test in an enviromental chamber

I am trying to think on the best way to report my results. Test setup:Oven with a profile running for 10 hours. temperature increses and decreses during that time. i have 4 UUTs inside the oven and i...

View Article

Send info to called sequence

Hello, I have a main test sequence which start up to 6 sequences, these sequences are identical and run in parallel.When calling a sequence(sub.seq), I need to send some info like the serial number and...

View Article

TestStand 2013 - Edit VI button disabled

Hello to everyone, I am using TestStand 2013 development system, and I also have Labview 2009 SP1 Full development system. I introduce a step with a labview action in my sequence. The Edit VI button is...

View Article


Use Array of Numbers as Select "Item to Compare"

Greetings, I'm curious in how to use an array of numbers as the value in the Select edit tab. Ideally my "cases" would execute a "Contains(Locals.arrayofnumbers,0)" expression. Basic Principle:1....

View Article

Can "call executable" use the "path" environment variable?

Hi,It seems when using the "call executable" step type that you either need to enter the absolute path of the executable, or the absolute working directory, in the "call settings" definition of the...

View Article


Sequence & SubSequence Results

Hi All,  I'm working ins TestStand 2013 in a Master Sequence that calls multiple subsequences. After execution, the Report is breaking the Results in SubSequence PASSED/FAIL and SubSequence Items...

View Article

Image may be NSFW.
Clik here to view.

TestStand Deploy function crashing

Has anyone else seen the TestStand Deployment wizard crash immediately upon launch?  I've inherited a project from another developer in my company, and I'm at the point where I'm trying to build a...

View Article


Image may be NSFW.
Clik here to view.

MetaToolbox XmlReader MetaInstaller MIF error

I keep getting this error when building TestStand installers.Any one know what this is about? ***************** Error: A tool or library returned an error. (Error code -20)Warning : loading xml file...

View Article

Get Teststand to set dos errorlevel

I want to launch Teststand and a Teststand sequence from a Generic Test in Microsoft Visual Studio. A Generic Test allows a command line based program to be called as part of a test provided it does...

View Article

Good NI Test Stand Examples For a Beginner (Using LabVIEW)

Hi everyone, I am new to using NI Test Stand.  I have gone through the "Getting Started with NI Test Stand" and "Using LabVIEW with Test Stand" documents. I know in the NI Test Stand Example folder...

View Article
Browsing all 6587 articles