Quantcast
Channel: NI TestStand topics
Browsing all 6524 articles
Browse latest View live

Passing Teststand Runtime container to LabVIEW

Hi Everyone,We can pass Teststand container to LabVIEW if the datatype is known. But, how we can parse the runtime container to LabVIEW? Please help with this!I've attached a snapshot for reference. I...

View Article


Teststand loading very slow if Labview Run-Time Engine is selected as adapter...

I have developed TestStand (2016 - 32-bit) program.I'm also using LabVIEW 2017 Development System for writing programs.I'm using LabVIEW simple user interface for running sequence file. (build EXE). If...

View Article


Image may be NSFW.
Clik here to view.

Remove Header of Sequence Execution View?

Any ideas on how to remove, change color of, or cover up the header of the Sequence Execution View?I can't see any properties to allow me to customize the header and I'm not able to put any UI elements...

View Article

Exclude "Begin Sequence" and "End Sequence" from text report in client...

I am generating a text report for my test (TestStand 2016 SP1), and have set my result text using the ModifyReportEntry callback.  However, I still get the "Begin Sequence" and "End Sequence"...

View Article

Customize date/time format in report file name

I want my TestStand UUTs reports (Batch process model) to have file name of the following format: UUT_yyyyMMddHHmmss.txt In particular, I want to use year-month-day for the date component, and 24-Hr...

View Article


Grouping Custom Types

Hi everyone,I'm fairly new to TestStand and I had a quick question about custom types and how to organize them to be less cumbersome when there are tons of them. I have an application that generates a...

View Article

Deployment utility slow build time

I am not very experienced with the deployment utility. I used it to create a deployable image, full deployment, using a workspace file. I did not exclude any files from vi.lib, user.lib, or instr.lib....

View Article

Log an Array with Additional Results into a SQL-Database

Hello,I tried to log an array of Numbers [0...999] into a SQL Server Database with the schema "Generic Recordset (NI)" and get the attached Error. If I don`t log the array, everything works fine. Has...

View Article


Numeric limit test without a VI?

I have a measurement that was stored as a variable in a previous step and now I need to put it in a numeric limit test. How do I do this without a VI?

View Article


CVI module using openmp

Hi,I'm trying to use openmp in a cvi dll.If the dll is called from TestStand (CVI adapter), the function works but when I want to quit TestStand, TestStand hangs.If the dll is called from a cvi project...

View Article

pass fail tolerance

Is there a setting to include a test measurement tolerance, i.e. compared measurement should be between low limit - low tolerance and high limit+high tolerance. In other words, low limit is say 50+-1...

View Article

test report numeric format

How  do or can I set the numeric format, decimal places, of the TS v16 Test Report. Using Labview 2016 module to perform Multiple Numeric Test. The Measurement, High, Low Limit are read via 2D double...

View Article

Image may be NSFW.
Clik here to view.

IdentifyUUT TestStand model issue

I am using this dll to get the DUT serial number. It reports itself as broken every now and then. If I select a different function and then go back and select this same function, the broken arrow goes...

View Article


Image may be NSFW.
Clik here to view.

Soi kèo Brighton vs Manchester City, 21:00 ngày 12/05 – Nhà Cái m88 cập nhật...

 bạn có thể khởi đầu đặt cược với nút CƯỢC NGAY bên dưới w88 thể thao hoặc tiếp diễn tham khảo phần phân tách bên dưới để có thêm cơ sở trước khi đặt cược nhé.THƯỞNG đến 9.000.000 VNĐTHƯỞNG CHÀO MỪNG...

View Article

Change comparison type to LOG programatically

Hi All,I have a numeric limit test within a For loop (6 loops).4 of those tests, test the output between 4V and 6V (Comparison Type "GELE") but the last 2 require no comparison ("LOG").At the moment I...

View Article


Two reports with different steps recorded

In TestStand, I have two reports enabled in Result Processing.  I'd like one report to have all of the step results and the second report has "Result Recording Option" disabled for a number of the...

View Article

Remove Callback from TestStand Report

I have a number of callbacks in my TestStand sequence, e.g. ProcessModelPreStep, SequenceFilePostStep, etc.   I can disable result recording for all the steps within the callback.  Is there a way to...

View Article


TestStand (2016) Deployment - Different directories

I have a teststand workspace file that was created on a pc where the base directory was C:\TSProjects\Project-1The deployment built without a problem, deployed everything worked.  All the paths in the...

View Article

TestStand 2019 PushOK SCC

Anybody had any luck getting this to work on TS 64Bit in Windows 10?  I just installed the PushOK SCC (64 Bit 1.8.9.0) and it doesn't even show up as a source control options in the TS config.

View Article

Image may be NSFW.
Clik here to view.

Reloading VI parameter when Connector pane is modified and deleting that...

I have a VI call which has multiple parameterLater if I delete one control from the VI e.g: Boolean and reload the prototype in TestStand. It comes as strike-through in red.I want to remove entry in...