Custom Step Type on TS 2017 compatible with TS 2016, error -17339
Hi, I created a custom step type in TS 2017, and I checked the option in Version > Set Earliest TestStand Version that can Use this Type to 16.0.0.0.Then when I tried to load the step type in TS...
View Articlehttps://confidentpreneur.com/radiant-farms-
Eating a balanced dieteating a well-balanced dietThere is no food by itself and that can provide you with all the nutrients that are essential for the body to support itself, hence the term eating a...
View ArticleNo Report at Display
Hello I am new to TestStand. I was practising some exercise programs in the online training course for TestStand. Unfortunately, the software does not display any report after execution. The...
View ArticleHow to set custom limit
Hello,i want to use the LEGE limit type but also an additional check > 0Is this possible in one step?
View ArticleUSB8506/2
HelloFor an application using C# and USB8506 component with the "nixnet.dll"I have to send master request frame onto the lin bus and then read the slave response,to make that i use the sequence...
View ArticleIn the TestStand report it uses Limit.Low for equals and LT. This is...
I may being too picky but when I have an equals limit I want it called a Equals limit. When I use the LT it should be the High limit. I understand from a programming perspective this makes sense but...
View ArticleSomething like subVI but for teststand
Greetings friday people.I am quiet noob playing with TestStand, so please be patient with me. I would like to ask if there is some clever way to connect and hide a bunch of statements in TestStand....
View ArticleNI TestStand Log Results Run-Time Error
Hello Community, I am using TestStand 2016 32-bit & Labview 2016 32-bitI am working with the TestStand Simple UI in Labview. Recently I have been getting this error. I have never seen this error...
View ArticleSequence file documentation
Is there a way to dynamically create the sequence file documentation?
View ArticleImporting variables from .csv to be used to set channels and perform channel...
Is there a way to import a file like the one attached and loop through each row as opposed to creating a step to set each unique value and to check each unique limit?
View ArticleTools >> Update Sequence Files does not update Types
This post implies that Tools >> Update Sequence Files will update the Typeshttps://forums.ni.com/t5/NI-TestStand/Update-All-Sequence-files-automatically-Types/td-p/2319322But yet another post...
View ArticleHow to find the loop count for while loop?
hello, I want to find the loop counter when the while loop is running, without setting parameter for record additionally. Is there anyway possible for me?Thanks in advance.
View ArticleError when calling Veristand Logging Step in Teststand
Hi, I have been tasked with creating an automated test system which uses Teststand to sequence control of Veristand.I am more familiar with Veristand then Teststand, but when I found that someone has...
View ArticleTeststand 2014 runtime crashing on windows 10 version 1809 and 1803
Hello everyone! I hope I can explain the situation clearly, so first some background: 1.-We developed a test framework back in 2015.2.-This test framework has been working since then on 4...
View ArticleMultiple Unit Testing in sequential
Hello All, Currently i am using Teststand to create Test sequence to test my product. for example i have example.seq created and 6 products for testing. i have to run this example.seq with all my...
View ArticleUIMSG_Trace
Dear Members, Is anyone utilised the Default Teststand UI Messages? Whenever a step is executing I m getting the UIMSG_Trace(4) Event from Teststand to LabVIEW User Interface. I m trying to use the...
View Articlewindow properties appear if i use double click to edit a steptype teststand
Hello,I use Labview with Teststand API. if i use ctrl + E to edit the steptype it work but if i use double click, Teststand generated me the window properties and the edit Step.Have you some explication?
View Articlehow to use notification step for parallel testing
Hello All, Can anyone tell me how to use notification step in test stand with multiple main sequence. for example, i have Test_1.seq and Test_2.seq and expect to start run these two sequence in...
View ArticleError in Writing to CFG Files
Hi All, In my use-case, I have a custom Configuration Directory for TestStand and the directory is in Source code control. The files are made read only by the source code control. Whenever I open...
View ArticleProblem with data transition between TestStand and LabWindows
Hello Members, I am quite new with both TestStand and LabWindows and I have a problem like this. I have a string type variable in TestStand and I want to manipulate this data with LabWindows/CVI dll...
View Article