Hello,
For the records, and because it took me some time before finding a way to remove TestStand 2017 SP1 and install TestStand 2017 instead (not common, yes, see the firt issue here : ASAM Steps : VeriStand is not installed ). Hope this may help someone...
NI Package Manager display by default the installed components filtered by Product (checkbox). I selected TestStand 2017 SP1 for uninstall, reboot the computer, then install TestStand 2017, rebbot again... impossible to run the Sequence Editor. Symptom, the TestStand Version Selector showed only the 2017 SP1 version of TestStand, and not the 2017. And throws an error when trying to activate 2017 SP1.
Unchecking the Product Only checkbox in NI Package Manager, I finally found that TestStand 2017 SP1 RunTime was still present (not uninstalled when removing TestStand 2017 SP1).
Removing the SP1 runtime and reinstalling TestStand 2017 finally fixes the issue.
Is that behavior expected ? I mean, why leaving the RunTime on my computer, installed (I guess) with TestStand development tools, when I uninstall TestStand (2017 SP1 in this case) ?
Regards,