Hi,
I have a test system with all the VIs saved in LabVIEW 2013 SP1 f5. Recently I updated my PC (not test system PC) to use patch f6 and edited one VI with it. After transferring this VI to the test system, TestStand didn't want to run this code module (red exclamation mark). After mass compile on the test station PC, everything started to work again.
Does this mean that the VIs need to be saved in the same patch version to properly work?
I do not use auto detect of the RTE because it seems to be slower configuration. Is that true?